Use this duct size calculator to find the round duct size that carries a given airflow at a sensible friction rate. Enter the airflow in cubic feet per minute (CFM) and choose a friction rate; the calculator shows the recommended round duct, an 8-inch-tall rectangular equivalent and the air velocity.
Duct size calculator
Enter the airflow a room needs and get the round duct size that carries it quietly.
- Recommended round duct
- –
- Rectangular option (8″ tall)
- –
- Air velocity
- –
Equal-friction estimate for smooth metal duct. Go one size up for flex duct, and confirm whole-system sizing with an ACCA Manual D design.
How this duct size calculator works
The calculator uses the equal-friction method, the most common approach for sizing residential ducts. It solves a standard friction equation for smooth round metal duct to find the diameter that carries your airflow at the chosen friction rate (pressure loss per 100 feet of duct), then rounds up to the next standard size. It also converts that round size to an equivalent rectangular duct using the standard equivalent-diameter formula, and calculates air velocity in feet per minute.
Choosing a friction rate
| Friction rate (in. w.c./100 ft) | Result | When to use |
|---|---|---|
| 0.06 | Larger ducts, quieter | Bedrooms, long runs, quiet priority |
| 0.08 | Standard | Most residential branch ducts |
| 0.10 | Smaller ducts, faster air | Short runs, tight spaces |
If you’re not sure, use 0.08.
How much airflow does a room need?
Systems typically move about 400 CFM per ton of cooling, shared among rooms according to their heating and cooling loads. As a rough guide, many bedrooms need about 80 to 150 CFM and large living rooms 200 CFM or more. Use our CFM per room calculator to estimate a room’s share.
Typical round duct capacities at 0.08 friction
| Round duct | Approximate airflow |
|---|---|
| 4 inch | Up to about 30–40 CFM |
| 5 inch | About 50–65 CFM |
| 6 inch | About 90–110 CFM |
| 7 inch | About 130–160 CFM |
| 8 inch | About 190–225 CFM |
| 10 inch | About 350–400 CFM |
Values are approximate for smooth metal duct; flex duct carries less.
Flex duct needs one size up
Flex duct’s ribbed liner creates more friction than smooth metal, and much more when it’s compressed or sagging. As a rule of thumb, go up one size for flex duct, keep runs short and fully stretched, and support them every 4 to 5 feet. See flex duct vs rigid duct.
Velocity matters for noise
Higher air velocity means more noise at registers. Many designers keep branch ducts below roughly 600 to 700 feet per minute and supply registers sized so air leaves quietly. If the calculator shows a high velocity, consider a larger duct or a lower friction rate.
Limits of a quick calculator
Real duct design accounts for total effective length (including fittings), the blower’s available static pressure, register and grille losses, and room-by-room loads. Contractors use ACCA Manual J for loads and Manual D for duct design. Use this duct size calculator for quick checks, DIY branch replacements and to sanity-check quotes, not to design a whole system.
When sizing isn’t the problem
Before upsizing a duct, check for simpler causes of weak airflow: a dirty filter, closed dampers, crushed or disconnected ducts and leaks. See weak airflow from vents and one room hotter than others.
Duct size calculator FAQ
What size duct do I need for 100 CFM?
About a 6-inch round metal duct at a 0.08 friction rate. Go to 7 inches for flex duct or a quieter result.
What size duct for a bedroom?
Most bedrooms use a 6- or 7-inch branch, depending on the room’s airflow need and run length.
Is a bigger duct always better?
No. Oversized ducts slow air too much, which can reduce throw at registers and cost more. Size to the airflow.
How do I convert round to rectangular duct?
Use an equivalent-diameter calculation. The calculator shows an 8-inch-tall rectangular option for each round size.
Does this calculator work for return ducts?
Returns are often sized at a lower friction rate for quieter operation. Use 0.06 as a starting point.