Air purifier CADR, short for clean air delivery rate, is the most useful number on an air purifier box. It tells you how much filtered air the unit delivers, measured in cubic feet per minute, for three pollutants: tobacco smoke, dust and pollen. A purifier with too low a CADR for your room will run all day and barely make a difference.
This guide explains what CADR means, how to use it, the common rules of thumb, and four easy steps to size a purifier correctly for any room.
Key takeaways
- CADR is measured in cubic feet per minute for smoke, dust and pollen; higher is better.
- Use the smoke CADR for fine particles; a common rule is smoke CADR of at least two-thirds of the room’s square footage.
- Air changes per hour (ACH) tells you how many times the purifier cleans the room’s air each hour; aim for 4 to 5 for allergies and smoke.
- Rated CADR is at the highest fan speed; quieter settings deliver less.

In this guide
What CADR means
CADR was developed by the Association of Home Appliance Manufacturers (AHAM). The EPA explains that if an air cleaner has a CADR of 250 for dust particles, it may reduce dust levels to the same concentration as would be achieved by adding 250 cubic feet of clean air each minute.
Each purifier is tested for three pollutants:
| CADR type | Represents | Use it for |
|---|---|---|
| Tobacco smoke | Small particles | Smoke, fine particles (PM2.5) |
| Dust | Medium particles | General dust |
| Pollen | Large particles | Pollen, larger allergens |
The EPA advises that to remove small particles, choose a portable air cleaner with a high CADR for tobacco smoke, since it represents the smallest particles. CADR is typically measured at the highest speed.
The two-thirds rule
AHAM’s long-standing guideline is that a purifier’s smoke CADR should be at least two-thirds of the room’s area in square feet (assuming 8-foot ceilings). For a 300 sq ft room, that’s a smoke CADR of at least 200. Units with an AHAM Verified label list a recommended maximum room size based on this rule, which aims for an 80 percent reduction in particle levels at steady state.
Air changes per hour
Another way to size a purifier is air changes per hour (ACH): how many times the purifier filters the room’s full volume each hour.
ACH = (CADR × 60) ÷ (room area × ceiling height)
For allergies, asthma or wildfire smoke, many experts suggest 4 to 5 ACH. The two-thirds rule works out to roughly 5 ACH in a room with 8-foot ceilings.
4 easy steps to size an air purifier
Step 1: Measure the room
Multiply length by width to get square feet. The EPA suggests this approach and, for open floor plans, considering the entire space the purifier would serve. Note the ceiling height.
Step 2: Calculate the CADR you need
- Two-thirds rule: smoke CADR ≥ room area × 2/3 (for 8-foot ceilings).
- Higher ceilings: scale up by ceiling height ÷ 8.
- Smoke or severe allergies: aim higher, toward 5 ACH or more.
Step 3: Check the speed you’ll actually use
Rated CADR is at full speed. If you’ll run it on a quiet setting overnight, choose a unit whose CADR at that setting meets your target. Some manufacturers publish CADR or airflow at each speed.
Step 4: Check noise, filter cost and ozone
Look at decibel ratings at your planned speed, the cost and lifespan of replacement filters, and make sure the unit doesn’t intentionally produce ozone. The EPA advises avoiding air cleaners that intentionally produce ozone.
Quick sizing table
| Room size (8 ft ceiling) | Minimum smoke CADR (two-thirds rule) |
|---|---|
| 100 sq ft | 67 |
| 150 sq ft | 100 |
| 200 sq ft | 133 |
| 300 sq ft | 200 |
| 400 sq ft | 267 |
| 500 sq ft | 333 |
For very large or open areas, two smaller purifiers in different spots often work better than one large unit.
Close the door. A purifier sized for a bedroom can’t keep up if the door is open to the rest of the house. Keep doors and windows closed while it runs.
Example calculations
Bedroom, 12 × 14 ft, 8-ft ceiling: 168 sq ft. Two-thirds rule: smoke CADR ≥ 112. For 5 ACH: (168 × 8 × 5) ÷ 60 = 112. A purifier with a smoke CADR of 120 to 150 fits.
Living room, 18 × 20 ft, 9-ft ceiling: 360 sq ft. Two-thirds rule adjusted for height: 360 × 2/3 × 9/8 = 270. Choose a smoke CADR of about 270 or more, or two smaller units.
Placement tips
- Place the purifier where you spend the most time, often near the bed.
- Keep 1 to 2 feet of space around intake and outlet.
- Don’t hide it behind furniture or in a corner.
- In a smoky environment, run it on high during the day and a quieter setting at night.
CADR vs HVAC filtration
Portable purifiers clean one room; HVAC filters clean the whole house when the fan runs. Many homes use both. See do air purifiers work and MERV ratings explained.
Common sizing mistakes
- Buying by “covers up to X sq ft” claims without checking CADR.
- Using dust or pollen CADR instead of smoke CADR for fine particles.
- Running a small purifier in a large open space.
- Running it on the lowest speed all the time.
- Ignoring filter replacement; a clogged filter delivers far less than its rated CADR.
A worked example
During wildfire season, a family wants cleaner air in a 14 × 16 ft bedroom with 8-foot ceilings: 224 sq ft. The two-thirds rule gives a smoke CADR of about 150. They choose a purifier with a smoke CADR of 210 at high and 140 on its quiet setting, so the quiet overnight setting still nearly meets the target. A PM2.5 monitor shows bedroom levels falling well below the hallway within an hour of closing the door.
Example sizing
| Room size | Suggested smoke CADR |
|---|---|
| 150 sq ft bedroom | About 100 |
| 250 sq ft room | About 165 |
| 400 sq ft living room | About 265 |
These follow the common two-thirds rule for rooms with 8-foot ceilings; larger CADR helps in rooms with higher ceilings or during smoke events.
Noise and real-world CADR
CADR is measured at the purifier’s highest setting. If you’ll run it on a lower, quieter setting, choose a model with a higher rating than the minimum. Check the noise level in decibels at the setting you’ll actually use, and look for the AHAM Verifide mark for independently tested clean air delivery rate numbers. See do air purifiers work.
Air purifier CADR: FAQ
What is a good CADR for an air purifier?
It depends on room size. Aim for a smoke CADR of at least two-thirds of the room’s square footage.
Is a higher CADR always better?
For particle removal, yes. But a higher CADR unit may be louder; check noise at the speed you’ll use.
What’s the difference between smoke, dust and pollen CADR?
They represent small, medium and large particles. Use smoke CADR for fine particles.
How many air changes per hour should an air purifier provide?
About 4 to 5 for allergies, asthma or smoke.
Does CADR apply to odors?
No. CADR measures particles only. Odor and gas removal depend on activated carbon.
The bottom line
Air purifier CADR is the key to buying a purifier that works. Measure your room, choose a smoke CADR of at least two-thirds of the square footage (more for smoke or high ceilings), check the CADR at the speed you’ll actually use, and keep the door closed. For EPA guidance, see its guide to air cleaners in the home.