Range hood ventilation is one of the most effective ways to improve indoor air quality. Cooking releases particles, moisture, grease and odors, and gas burners add combustion pollutants. A range hood vented outside captures and removes them at the source. A recirculating hood only filters grease and some odors.
This guide covers six simple rules for choosing, sizing and using a range hood.
Key takeaways
- Ducted hoods vented outside remove pollutants; recirculating hoods don’t remove gases or moisture.
- HVI recommends 100 CFM per linear foot of cooktop for wall hoods and 150 for island hoods.
- Hoods that are wider than the cooktop and mounted at the right height capture better.
- Very powerful hoods may need makeup air; check local code.
In this guide
1. Vent outside
Ducted hoods vented outside remove pollutants, moisture and heat. Recirculating hoods filter grease and some odors through carbon but return air to the kitchen.
2. Size it
| Hood location | HVI recommended | Minimum |
|---|---|---|
| Against a wall | 100 CFM per linear foot | 40 CFM per linear foot |
| Island | 150 CFM per linear foot | 50 CFM per linear foot |
A 30-inch (2.5 ft) wall hood: about 250 CFM recommended. See HVI’s ventilation guidance.
3. Cover the cooktop
A hood at least as wide as the cooktop, ideally a few inches wider, captures more.
4. Use good ducting
Use smooth metal duct of the size the hood specifies, with as few bends as possible. Never vent into the attic or wall cavity.
5. Makeup air
Very powerful hoods can depressurize a tight house, affecting gas appliances. Many codes require makeup air for hoods above a certain CFM.
6. Use it every time
Turn it on before cooking and leave it on 10 to 15 minutes after. Use back burners. See gas stove indoor air quality.
See our main guide, how to improve indoor air quality.
Ducted vs recirculating range hoods
| Ducted (vented outside) | Recirculating (ductless) | |
|---|---|---|
| Removes smoke and particles | Yes | Partly, through filters |
| Removes moisture | Yes | No |
| Removes combustion gases | Yes | No |
| Removes odors | Yes | Partly, with carbon filters |
| Installation | Needs a duct to the outside | Easier |
| Maintenance | Clean grease filters | Clean grease filters and replace carbon filters |
If you have any choice, a ducted hood gives far better range hood ventilation. Recirculating hoods are a fallback for kitchens where a duct to the outside is impossible.
How to tell if your hood vents outside
- Look for a duct running from the top of the hood into the cabinet above, the wall or the ceiling.
- Check outside the house for a vent cap near the kitchen.
- Look inside the hood: a recirculating hood usually has charcoal filters behind the grease filters and vents out through slots at the top front.
- Hold a tissue at the exterior cap while the hood runs on high; it should blow outward.
Some microwave-over-range units can be set up either way; check how yours is installed.
Common duct mistakes
- Venting into the attic, soffit or wall cavity. Grease and moisture cause mold and fire risk. The duct must terminate outside with a proper cap.
- Using flexible foil duct. It traps grease and restricts airflow. Use smooth metal duct.
- Downsizing the duct. A 6-inch duct on a hood designed for 8 inches cuts airflow sharply.
- Too many elbows. Each bend reduces airflow; keep runs short and direct.
- No backdraft damper. Without one, cold air and insects can come in when the hood is off.
Capture efficiency matters more than CFM
A very powerful hood that’s narrow or mounted too high can still let smoke escape, while a moderately powered hood that’s wide and mounted at the correct height captures most of it. Look for:
- A hood at least as wide as the cooktop, ideally 3 inches wider on each side.
- A deep canopy that covers the front burners.
- Mounting height within the manufacturer’s recommended range.
Using your hood well
- Turn it on before you start cooking, not when smoke appears.
- Use the back burners whenever possible.
- Use higher speeds for frying, searing and stir-frying.
- Leave it running for 10 to 15 minutes after you finish.
- Clean grease filters every month or two, in the dishwasher or with hot soapy water.
Makeup air explained
When a hood exhausts a lot of air, the same amount must come back in somewhere. In tight houses, it may come down chimneys and flues, which can pull combustion gases from fireplaces, water heaters or furnaces back into the home. The IRC requires makeup air for kitchen exhaust hoods above 400 CFM in many cases. A makeup air system brings in outdoor air, often through a motorized damper interlocked with the hood. Ask your installer whether your hood requires it.
Good range hood ventilation is one of the most effective ways to improve kitchen air, reduce moisture and keep cooking smells from spreading through the house.
Range hood ventilation FAQ
Does a range hood need to vent outside?
For removing pollutants and moisture, yes.
What CFM range hood do I need?
About 100 CFM per foot of cooktop for wall hoods.
Are recirculating hoods worth it?
They help with grease and some odors, but not combustion gases.
Should I run the hood when cooking?
Yes, every time.